How to do a good job of preventing moisture from stacking racks
1. To study and explore the mechanism and law of IV transfer. Moisture transfer itself is a very complicated problem. In order to simplify the calculation, in order to simplify the calculation, we used the steady-state moisture transfer theory, taking the high temperature and high humidity weather as the basis for the design of the outside of the warehouse. Therefore, a reasonable enclosure structure of the warehouse shelf material is selected, and the thickness and arrangement method of the welding materials of various stacking racks are calculated to ensure that the humid air outside the warehouse cannot be transferred to the warehouse during the high temperature and high humidity IV season. The warehouse shall ensure proper humidity and microclimate.
2. The warehouse where the stacking racks are placed must be sealed as a whole. It is difficult to guarantee the moisture-proof of the warehouse by design calculation alone. It is also necessary to work hard on the general layout, the flat profile design of the single unit, the construction and treatment of the enclosure structure (wall, roof, ground, doors and windows, etc.), as well as the construction technology and construction methods. , Make Kuqiong form a canned box-like airtight, so that the moist air outside the warehouse can not be introduced into the warehouse.
3. Relying on meticulous design and meticulous construction alone cannot fully meet the requirements in many cases, and some effective management systems and management methods must be adopted. For example, ventilation between stacking racks should be carried out at the right time, auxiliary dehumidification should be carried out when necessary, drainage and leakage repair of the warehouse, and maintenance and management of the warehouse should be done at any time.
4. The humidity inside and outside the stacking rack warehouse as well as the wind direction, wind speed, air pressure, etc. should be measured frequently and regularly. When conditions permit, the moisture conductivity of the warehouse should also be measured to accumulate more moisture-proof test data. , To better grasp the moisture-proof law of the warehouse. Only from the comprehensive management of the warehouse's moisture-proof calculation, building structure, careful construction, careful management, and moisture-proof testing, can the moisture-proof problem of the warehouse be solved economically and reasonably.